IVD

IVD Clinical and Post-Market Services

Performance evaluation, post-market surveillance and PMPF for in vitro diagnostics under the IVDR, and analytical and clinical validation for FDA submissions.

  • 360+expert consultants partnered with Apotech
  • 98%client retention

Trusted by medical device and diagnostics leaders worldwide

Swiss Precision Diagnostics logoMedtronic logoMölnlycke logoP&G logoPolarSeal logoPurple Surgical logoHypnoVR logoCAIRE logoKid Solutions logoTribun Health logoPrediSurge logoLucida Medical logoClearblue logoSysnav logoBalt logoAIVF logoPhilips Healthcare logo

Our IVD clinical and post-market services

Performance evidence that stands up to notified body and FDA review.

Performance evaluation plan

Plans that set out how scientific validity, analytical and clinical performance will be demonstrated.

Explore Performance evaluation plan

Performance evaluation report

Reports that bring the evidence together into clear conclusions on performance and benefit-risk.

Explore Performance evaluation report

PMS and PMPF

Post-market surveillance, PSURs and post-market performance follow-up under the IVDR.

Explore PMS and PMPF

FDA validation and submissions

Analytical and clinical validation strategy and FDA premarket submissions for IVDs.

Explore FDA validation and submissions

How IVD performance evidence fits together

One strategy across plan, report and post-market data.

  1. 01Plan

    Write the performance evaluation plan and define the evidence needed.

  2. 02Gather

    Collect scientific validity, analytical and clinical performance data.

  3. 03Evaluate

    Write the performance evaluation report and identify gaps.

  4. 04Fill gaps

    Run performance studies or PMPF activities where needed.

  5. 05Update

    Feed PMS and PMPF data back into the PER and PSUR.

Related services: IVD CE marking · IVD quality systems · FDA submissions for IVDs

Featured case studies

Sorry, we couldn't find any posts. Please try a different search.

What is performance evaluation for IVDs?

Under Article 56 and Annex XIII of the IVDR, every IVD needs a performance evaluation showing three things: scientific validity (the link between the analyte and a clinical condition), analytical performance (how well the device detects or measures the analyte) and clinical performance (how well results relate to the clinical condition in the target population).

The evaluation is documented in a performance evaluation report and kept up to date with post-market surveillance and PMPF data throughout the life of the device.

  • Legal basisArticle 56 and Annex XIII of the IVDR.
  • Performance studiesCovered by Articles 57 to 77 of the IVDR, with MDCG 2025-5 questions and answers.
  • PSURsClass C and D devices need a PSUR updated at least annually; Class A and B need a PMS report.

IVD clinical and post-market FAQs

What is the difference between a PEP and a PER?

The PEP plans the performance evaluation before work starts; the PER documents the evidence and conclusions.

Do we need new clinical performance studies?

Not always. Existing literature, routine diagnostic testing data and previous studies may be enough, depending on the device, its class and its claims.

Ready to get started?