MedTech

Clinical and Post-Market Services for Medical Devices

Clinical evaluation, post-market surveillance, PMCF and clinical investigation support that gives notified bodies and regulators the clinical evidence they expect, across the device lifecycle.

  • 360+expert consultants partnered with Apotech
  • 98%client retention

Trusted by medical device and diagnostics leaders worldwide

Swiss Precision Diagnostics logoMedtronic logoMölnlycke logoP&G logoPolarSeal logoPurple Surgical logoHypnoVR logoCAIRE logoKid Solutions logoTribun Health logoPrediSurge logoLucida Medical logoClearblue logoSysnav logoBalt logoAIVF logoPhilips Healthcare logo

Our clinical and post-market services

Clinical evidence work that holds together from first evaluation plan to the latest PSUR.

Clinical evaluation plan

Define the clinical evidence your device needs, the sources you will use and how they will be appraised, as required by Annex XIV of the EU MDR.

Explore Clinical evaluation plan

Clinical evaluation report

Literature search, state of the art, data appraisal and benefit-risk conclusions written to the standard notified bodies expect.

Explore Clinical evaluation report

Post-market surveillance

PMS plans, PSURs, PMS reports, complaint trending and vigilance processes for the EU, UK and other markets.

Explore Post-market surveillance

PMCF

PMCF plans, studies and evaluation reports that keep clinical evidence current after certification.

Explore PMCF

Clinical investigations

Study design, clinical investigation plans, investigator brochures and EU, UK and FDA submissions.

Explore Clinical investigations

How clinical evidence fits together

One clinical strategy, kept consistent across every document a notified body will read.

  1. 01Plan

    Set the clinical evaluation plan, intended purpose, claims and the evidence needed to support them.

  2. 02Gather

    Search and appraise literature, equivalent device data and your own pre-market and post-market data.

  3. 03Evaluate

    Write the clinical evaluation report and benefit-risk conclusions, and identify gaps.

  4. 04Fill gaps

    Design PMCF activities or clinical investigations where existing data is not enough.

  5. 05Update

    Feed PMS, PMCF and vigilance data back into the clinical evaluation, risk management and PSUR.

Related services: ISO 14971 risk management · CE marking · IVD clinical and post-market

Featured case studies

EU-MDR Technical File Authoring

EU-MDR Technical File Authoring Introduction Medical Technology Client Our client is a leader in high-quality, surgeon-designed, innovative ophthalmic products located in the US with operations globally. These range from Class I through to Class III devices. Apotech Consultants Our consultants take a risk-based approach to improve quality and compliance, and implement practical solutions for your…

Read More

ISO 14155 Audits – Europe, US & Australia

A Class III cardiovascular implant manufacturer needed ISO 14155 clinical investigation audits across Europe, the US and Australia.

Read More

QMS Implementation for Class III Medical Device

QMS Implementation for Class III Medical Device Introduction Streamlining ISO 13485 Certification for a connected medical device. The company is a highly innovative start up, which has developed a best-in-class pacemaker. At the time of engaging with them they were on the road to CE Marking. Apotech Team Worked full time on the project: balanced…

Read More

What is clinical evaluation under the EU MDR?

Clinical evaluation is the ongoing process of generating, collecting, analyzing and assessing clinical data to verify the safety, performance and clinical benefit of a device when used as intended. Article 61 and Annex XIV of the EU MDR set out what manufacturers must do, and notified bodies record their assessment in a clinical evaluation assessment report (CEAR).

It does not end at certification. Post-market surveillance and post-market clinical follow-up feed new data back into the clinical evaluation throughout the life of the device.

  • Legal basisArticle 61 and Annex XIV of the EU MDR set the requirements for clinical evaluation and PMCF.
  • Notified body reviewNotified bodies document their assessment using the MDCG 2020-13 clinical evaluation assessment report template.
  • Key guidanceMDCG 2020-5 covers equivalence, MDCG 2020-6 covers legacy devices, and MDCG 2020-7 and 2020-8 provide PMCF plan and report templates.
  • PSURsClass IIb and III devices need a PSUR updated at least annually; Class IIa at least every two years.

Clinical and post-market FAQs

Which documents make up the clinical evidence for a device?

At minimum the clinical evaluation plan and report, the PMS plan, the PMCF plan and evaluation report (or a justification for not doing PMCF), and the PSUR or PMS report. For implantable and Class III devices, the Summary of Safety and Clinical Performance (SSCP) as well.

Can we use equivalence to another device?

Sometimes. Equivalence must be shown on technical, biological and clinical characteristics, and for Class III and implantable devices you usually need a contract giving full access to the other manufacturer’s technical documentation. MDCG 2020-5 explains the expectations.

Do you work on IVDs as well?

Yes. IVDs follow performance evaluation under the IVDR rather than clinical evaluation. See IVD clinical and post-market services.

Can you update our documents after notified body questions?

Yes. We help manufacturers respond to notified body questions on clinical evaluation, PMCF and PMS, and update documents so the same issues do not come back.

Ready to get started?

Tell us what you need, where and when. Your Business Manager will come back to you with a scope and proposal.